8.4″ 1024×768 TFT LCD PV08417D0120S

The Kingtech PV08417D0120S is an 8.4-inch TFT LCD with a 1024 × 768 XGA resolution, 4:3 format and LVDS input. It combines a 1000 cd/m² typical backlight with a −30 to +80 °C operating range. That combination makes it a candidate for machine-control displays and instrumentation installed in bright work areas or enclosures with large temperature swings.

Screen size
8.4 in
Resolution
1024 × 768 px
Brightness
1000 nits
Display interface
LVDS
Request an Evaluation Sample

Model: PV08417D0120S

Technical Specifications

Module specifications
Resolution1024 × 768 (XGA), 4:3
Display interfaceLVDS, 20-pin signal connector
Luminance1000 typical / 800 minimum cd/m² at 100% PWM
Operating temperature−30 to +80 °C
Storage temperature−30 to +80 °C
Outline199.5 × 149.0 × 9.60 mm
Active area170.496 × 127.872 mm
TouchTouch configuration unconfirmed
Design and selection considerations
Image geometryThe native 1024 × 768 raster and 170.496 × 127.872 mm active area make it possible to check both the software layout and the physical window of a 4:3 product.
Brightness and uniformityThe optical table lists 800 cd/m² minimum brightness and 75% minimum uniformity at full PWM. Use both when screening a display for an interface with large, light backgrounds.
Contrast and colorTypical contrast is 1500:1 under the datasheet test conditions. The module supports 16.7 million colors. Evaluate the application's smallest labels, dim indicators and dark backgrounds under expected room lighting.
PWM controlThe backlight specification lists a 100 Hz to 30 kHz PWM range. Choose the controller setting with the backlight input specifications and the equipment's dimming needs in mind.
Connectors and powerThe LVDS logic supply is 3.3 V. The backlight has its own connector and a 12 V typical input. Review the two connections separately during schematic and cable design.

1000 typical / 800 minimum cd/m² at 100% PWM

Documents & Drawings

Model Datasheet & Mechanical Drawing

Request model-level documents for your evaluation.

Request Documents
Download General Catalog

Typical Applications

Wide-temperature industrial control panels

The −30 to +80 °C operating range supports evaluation for equipment that experiences cold starts or elevated internal temperatures. Measure the conditions around the installed module when qualifying a sealed or heated enclosure.

XGA equipment refreshes

An existing 4:3 interface can retain its native layout. Compare the 199.5 × 149.0 × 9.60 mm outline, mounting constraints, connector mating parts and LVDS timing before considering the panel as a replacement.

Instrumentation in bright work areas

The 1000 cd/m² typical output gives designers a defined starting point for managing ambient light. Evaluate the display behind the intended protective window and at the brightness levels operators will use.

Display Features

  • Optical performance and backlight control: The optical specification lists 800 cd/m² minimum and 1000 cd/m² typical brightness at 100% PWM duty. It also lists 1500:1 typical contrast and 80% typical luminance uniformity. PWM dimming lets the host adjust backlight output for different lighting conditions. The rated 70,000-hour typical LED lifetime is measured to 50% of initial brightness at 25 °C and 100% PWM.
  • Electrical and mechanical integration: The module uses a 20-pin LVDS signal connector and a 3.3 V logic supply. The backlight has its own connection and is specified at a 12 V typical input. The overall outline is 199.5 × 149.0 × 9.60 mm, with a 170.496 × 127.872 mm active area. For an existing XGA design, check connector pin assignment, LVDS timing and enclosure clearances against the datasheet before committing to the mechanical design.
  • Application fit: Consider this panel for industrial HMI systems, test equipment and control terminals where the host is already designed around a 4:3 LVDS display. Use the specified temperature and brightness values to screen the panel, then evaluate readability in the final installation.
  • Design-in checklist: Compare the host LVDS timing and signal assignment against the V1 specification.
  • Design-in checklist: Check logic and backlight supplies, the backlight enable signal and PWM control.
  • Design-in checklist: Verify the outline, connector clearance and active-area alignment in the mechanical layout.
  • Design-in checklist: Run readability and dimming checks on the sample at the expected viewing positions.
Discuss Your Requirements

Technical FAQ

What is the specified backlight lifetime?

The datasheet lists 70,000 hours typical to 50% of initial brightness at 25 °C and 100% PWM.

How do I compare brightness across panels?

Review the specified minimum and typical values together with the PWM duty and measurement conditions.

What should I share for a replacement review?

Provide the current panel model, host connector and pinout, enclosure drawing, target brightness and operating temperature range.

Request a Quote (RFQ)

Model: PV08417D0120S
Request a quote, evaluation sample or product documents.